filter cart.jpg

Parker Hydraulic offers the Icount PD particle detector diagnostic filter cart. Featuring inventive technology in solid particle detection and contamination analysis, the Icount can be mounted to the standard frame of the filter cart for improved monitoring of a hydraulic system. Coupled with the filter cart, the Icount PD is an effective solution for fluid management and contamination control. Features of the solution include prolonged fluid life and reduced machine downtime. Intuitive communication protocols improve user setup, operation, and output information. The detector offers a minimum sample time of 3 s and an internal flow range of 40 to 140 mL/min (1.4 to 4.7 oz/min) with a working pressure of 2 to 420 bar (29 to 6090 psi). Regulated 9 to 40 V dc, the filter cart's case is constructed of bead-filled nylon for durability.